Having a Problem?

(continued)

Situation

Probable Cause

&

Solution

The door opens but

w on't close:

1, If the opener lights blink, check the safety reversing sensor. See page 23.

2. If the opener lights do not blink and it is a new installation, check the down force.

See Adjustment Step 2, page 29. For an existing installation, see below.

Repeat the safety reverse test after the adjustm ent is com plete.

The door reverses for

no apparent reason
and opener lights

don't blink:

1. Is something obstructing the door? Pull the red emergency release handle. Operate

the door manually. If it is unbalanced or binding, call for professional garage door
service.

2. Clear any ice or snow from the garage floor area where the door closes.

3. Review the force adjustment procedures on page 29.

4. If door reverses in the fu//yc/osed position, decrease the travel limits (page 28).

Repeat safety reverse test after adjustm ents to force or travel lim its. The need

for occasional adjustm ent of the force and lim it settings Is norm al. W eather

conditions In particular can affect door travel.

The door reverses for

no apparent reason

and opener lights

blink for 5 seconds
after reversing:

Check the safety reversing sensor. Remove any obstruction or align the receiving eye.
See page 23.

The opener lights:

...

don't turn on:

Replace the light bulbs (75 watts maximum). Use a

standard

neck garage door opener

bulb if regular bulb bums out.

..,

don't turn off:

Is the Light feature on? Turn it

off.

The opener strains or

m axim um force Is

needed to operate
door:

The door may be out of balance or the springs are broken. Close the door and use the

emergency release to disconnect the trolley. Open and dose the door manually. A properly
balanced door will stay in any point of travel while being supported entirely by its springs. If it
does not. disconnect the opener and call a professional garage door serviceman.

Do not

increase the force to operate the opener.

The opener m otor

hum s briefly, then
w on't w ork:

1. The garage door springs are broken. See above.

2. If the problem occurs on the first operation of the opener, door may be locked.

Disable

the door lock.

If the chain was removed and reinstalled, the motor may be out of phase.

Remove the chain; cycle the motor to the down position. Observe the drive sprocket.
When it turns in a clockwise direction and stops in the down position, reinstall the chain.

Repeat the safety reverse test after the adjustm ent is com plete.

The opener w on't

operate due to

pow er failure:

1. Use the emergency release to disconnect the trolley. The door can be opened and closed

manually. When the power is restored, press the Door Control push button and trolley will
automaticEdly reconnect (unless trolley is in lockout position.) See page 32.

2. The Emergency Key Release accessory (for use on garages with no service door)

disconnects the trolley from outside the garage in case of power failure.

The chain droops

or sags:

It is normal for the chain to droop slightly in the closed door position. Use the

emergency release to disconnect the trolley. If the chain returns to normal height when
the trolley is disengaged and the door reverses on a one-inch board, no adjustments
are needed (see page 11).

35

Advertising
This manual is related to the following products: