Craftsman 139.53975SRT User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Before you begin, survey your garage area to

see whether any of the conditions below appiy
to your instailation.

Horizontal and vertical reinfoncement

is needed for lightweight garage doors

(fiberglass, steel, aluminum, door

with glass panels, etc.).

See page 24 for details.

FINISHED CEILING
Support bracket &

fastening hardware

is required.

See page 17.

' Safety Reversing Sensor

Floor must be level

across width of door.

Based on your particular requirements, there are

several instailation steps which might call for

materials and/or hardware not included in the carton.

• Step 1. page 12 - Look at the wall or ceiling above

the garage door. The header bracket must be
securely fastened to structural supports.

• Step 5, page 17 - Do you have a finished ceiling in

your garage? If so, a support bracket and
additional fastening hardware may be required.

• Safety reversing sensor, page 21 - Depending

upon garage construction, extension brackets (see
Accessories page 38) or wood blocks may be
needed to fasten sensors to mounting locations.

• Step 10, page 22 - Floor mounting of the safety

reversing sensor will require hardware not
provided.

• Step 11, page 24 - Do you have a steel, aluminum,

fiberglass or glass panel door? If so, horizontal

and vertical reinforcement is required.

• Look at the garage door where it meets the floor.

It must close on the floor all the way across.
Otherwise, the safety reverse system may not

work properly. See page 30. Floor or door should

be repaired.

Garage_

Door

Chain

Closed Position

Emergency Release

Rope & Handle

• The opener can be installed within 4 feet to the left

or right of the door center if there is a torsion spring
or center bearing plate in the way of the header
bracket or door bracket area. If your door has
extension springs, the opener must be installed in

the center of the door. See pages 12 and 24.

• Do you have an access door in addition to the

garage door? If not. Model 53702 Emergency Key
Release is required. See page 38.

• If your door is more than 7 feet high, see the rail

extension kits listed on page 38.

You may find it helpful to refer back to this page as you proceed with the installation of your opener.

Advertising
This manual is related to the following products: