CellarPro 4000SWC SPLIT SYSTEM WATER COOLED, 7649 User Manual

Page 28

Advertising
background image

28

V10.14

System R-134a Charge Guidelines

Actual

Line

Length

(ft)

4000Swc, Shwc

8000Swc

5

1.35

3.31

10

1.55

3.52

15

1.75

3.72

20

1.95

3.92

25

2.15

4.13

30

2.35

4.33

35

2.55

4.53

40

2.75

4.74

45

2.95

5.04

50

3.15

5.25

55

3.35

5.46

60

3.55

5.68

65

3.75

5.89

70

3.95

6.11

75

4.15

6.32

80

4.35

6.53

85

4.55

6.75

90

4.75

6.96

Note:

1) Actual charge may vary - follow charging instructions

detailed under Item 6 in the section titled Evacuation,

Leak Detection, and Charging (above).

2) Lines sized according to Line Sizing Chart assuming actual

line length plus 10 equivalent feet for fittings losses.

System R-134a Charge Guidelines

System Charge (lbs) by Split Water Cooled

System Model


Ducting for the Evaporator (4000Swc Models)

Cold air exhaust and return (from the evaporator) can be ducted with our front duct
hood up to 50 equivalent feet using

8” diameter insulated ducting, or 100 equivalent

feet with an auxiliary inline fan. Our front duct kit is compatible exclusively with our
4000Swc cooling units.

Before attaching the front duct hoods, remove the front grill (if present) from the
front of cooling unit.

We also offer a remote control panel kit that can be installed remotely (up to 10
feet) from the cooling unit, either inside or outside the cellar, and a bottle probe (10
foot cord) that can be plugged into the cooling unit.