Operations

4. SOUND

a. ALL

Slide the MIC switch to the ALL position. The sound indicator

light and sidebar lights illuminate when continuous sound is

detected for 12 seconds or longer in the room by the built-in

microphone. After another 10 second delay, the lamp will flash

on for one second, off for one second, on again for one second

and repeat until two minutes have passed; the bed shaker will also

vibrate while the lamp flashes.

b. MAIN

The light indicates the presence of sound, but it will not trigger

the lamp to begin flashing or any other indicator.

c. OFF

The sound indicator light and the monitoring function are disabled.

NOTE: The sound indicator light illumination function is also activated

when a signal is received from the optional Baby Sound Monitor (AMBX).

The position of the MIC switch is irrelevant – AMBX activates the sound

indicator light regardless of the position of the MIC switch.

AlertMaster

PHONE

CLOCK

ALARM

DOOR

SOUND

MOTION

Operations

5. ALARM

You must purchase the optional Audio Alarm Transmitter (Model AMAX)
from Clarity to use this function. When a signal is received from the
Audio Alarm Transmitter, the indicator light illuminates, and the lamp will
turn on for five seconds, off for two seconds, on again for two seconds
and repeat until two minutes have passed; the bed shaker will also
vibrate while the lamp flashes.

AlertMaster

PHONE

CLOCK

ALARM

DOOR

SOUND

MOTION

6. MOTION SENSOR LIGHT

You must purchase the optional Motion Sensor (Model AMSX) from
Clarity to use this function. When a signal is received from the Motion
Sensor, the indicator light illuminates, and the lamp will turn on for one
second, off for one second and repeat until two minutes have passed; the
bed shaker will also vibrate while the lamp flashes.