Room layout-above ground model 224xlc with lift – Dynojet 424xlc2: Pre-Installation Guide User Manual

Page 23

Advertising
background image

D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N

Above Ground Model 224xLC Dyno

Version 5

Pre-Installation Guide for Model 224 and 424 Automotive Dynamometers

15

R

OOM

L

AYOUT

—A

BOVE

G

ROUND

M

ODEL

224

X

LC

WITH

L

IFT

Use the following information to locate various dyno equipment, power outlets,

compressed air, and properly set up your dyno room.
For optimal eddy current brake cooling, the brake should turn in the direction of the

arrows on the rotor. The dyno will perform correctly in either direction, but cooling of

the rotors may be less effective when turning in the direction opposite of the arrows.
The eddy current brake is set up to run on the right side of the vehicle type (front/rear

wheel drive) you test most often. If this does not work for your dyno room, contact

Dynojet. Figure 7 shows a front wheel drive setup.

Figure 7: Room Layout—Above Ground Model 224xLC with Lift

798.00 cm

(314.25 in.)

128.37 cm
(50.54 in.)

228.60 cm
(90.00 in.)

382.27 cm

(150.50 in.)

97.48 cm

(38.38 in.)

42.19 cm

(16.61 in.)

58.42 cm

(23.00 in.)

65.58 cm

(25.82 in.)

AD437

provide 110V outlets for the:

•computer

•monitor

•dyno electronics

provide one 240V outlet

for the eddy current brake

locate the following items

close to the vehicle:

•dyno electronics

•computer

•monitor

provide one 240V

outlet for the lift

power unit

338.00 cm

(133.00 in.)

provide compressed air:
•to release the air brake

•to run the AFR-4 air pump

front of dyno

rear wheel drive

front of dyno

front wheel drive

shown here