Pre-Installation Guide for Model 224 and 424 Automotive Dynamometers

D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
In Ground Model 224xLC Dyno

18

R

OOM

L

AYOUT

—I

N

G

ROUND

M

ODEL

224

X

LC D

YNO

Use the following information to locate the necessary dyno equipment, power outlets,
compressed air, and properly set up your dyno room.
For more detailed information about the pit requirements, refer to the pit
specifications (P/N 98219103) you received from your salesman.
For optimal eddy current brake cooling, the brake should turn in the direction of the

arrows on the rotor. The dyno will perform correctly in either direction, but cooling

of the rotors may be less effective when turning in the direction opposite of the

arrows.
The eddy current brake is set up to run on the right side of the vehicle type (front/rear
wheel drive) you test most often. If this does not work for your dyno room, contact
Dynojet. Figure 9 shows a front wheel drive setup.

Figure 9: Room Layout—In Ground Model 224xLC Dyno

AD440

provide one 240V outlet

for the eddy current brake

locate the following items

close to the vehicle:

•dyno electronics

•computer

•monitor

provide 110V outlets for the:

•computer

•monitor

•dyno electronics

381.00 cm

(150.00 in.)

279.40 cm

(110.00 in.)

144.78 cm

(57.00 in.)

provide compressed air:
•to release the air brake

•to run the AFR-4 air pump

front of dyno

rear wheel drive

front of dyno

front wheel drive

shown here

pit conduit

pit outline