Pre-Installation Guide for Model 224 and 424 Automotive Dynamometers

A P P E N D I X B
Power Requirements and Installation—Excluding North America and Japan

B-6

I

NSTALLING

THE

W

ALL

R

ECEPTACLE

The wall receptacle is a single 240 volt 30A dedicated circuit with a ground.

Note: The actual wall receptacle may be different from the image shown in
Figure B-2; however, the installation instructions are the same.

The cable carrying the power to this receptacle should be 4.0 mm

2

(ten gauge) or

larger. Check with local building codes for the correct size.
1

Connect one of the 240V legs to the N terminal (no color).

2

Connect the other 240V leg to the L terminal (no color).

3

Connect the ground conductor to the green terminal.

Figure B-2: Wiring the Wall Receptacle

N terminal

L terminal

ground terminal

(green)