Country Flame LR-01 User Manual

Page 23

Advertising
background image

Version 1.0

Page 23


6. The LR-01 is designed to accept installations using a horizontal vent through an exterior wall.

A horizontal flue pipe installation should be a minimum of 24” from pellet stove vent pipe to
flue cap connection. FIGURE 1 shows a through the wall exterior vent installation.

WALL THIMBLE

EXTERIOR WALL

FLUE PIPE

JET CAP

FLUE PIPE

CLEAN OUT "T"

EXTERIOR WALL

JET CAP

FIGURE 1: HORIZONTAL VENT PIPE (2 options)

7. FIGURE 2 shows a traditional, as well as more efficient, flue pipe installation. Note the

dimensions that are required to be maintained in this type of installation. Dimensions are A
equals a minimum of 24”, B equals a minimum of 3”, and C equals a minimum of 6”. Again,
check with the flue pipe manufacturer’s installation instructions and code requirements for
exact specifications. DIMENSIONS:

FIGURE 2: TRADITIONAL VENT PIPE