Country Flame LR-01 User Manual

Page 8

Advertising
background image

Version 1.0

8

DESCRIPTION

The LR-01 Pellet Stove is designed to sit on a pedestal or legs as a freestanding unit or
can be installed as in insert with the optional shroud and split lid. The basic stove unit
without shroud or pedestal measures 22 3/4” high by 26” wide and 19 3/4” deep.
Centered above the firebox glass front door is a louvered vent through which room
convection air is passed.

The right side of the unit has a rheostat control knob to vary the speed of the room air
blower. The left side of the unit has a control panel for the integrated “Intelli-Choice
control board. The controls include 5 heat settings, an ON/OFF switch and lights to
indicate proper operation. On the back of the unit are located a 3” tube for installation
of outlet vent pipe and a hole for installation of a 1 ½” inlet air tube. The top of the unit
lifts up for easy loading of fuel. An optional two piece lid is available if the Little
Rascal is to be used as an fireplace insert.

1. The Country Flame LR-01 is remarkably simple and safe in its operation. From a

relatively small firebox over 40,000 BTU’s per hour can be produced.


2. The fuel (APFI approved) is loaded into the hopper. After the fire has been lit (see

lighting instructions) an angled drive auger delivers fuel, a few pellets at a time,
into the firepot at a controlled rate. The combustion blower delivers directed air
input, creating a vigorous, efficient burn. The hot exhaust gases are drawn through
a 14-tube heat exchanger, which extracts heat from the gases as they are discharged
to the exhaust pipe.

3. A second blower circulates room air through the heat exchanger, pushing warm air

into the room from the tubes located just above the door. The room air blower is
intended to run continuously and can be easily controlled to maintain a uniform
temperature.


4. The Pellet Stove will deliver a constant amount of heat, which can be varied by

setting the fuel control knob. Besides initial lighting of the unit, the only regular
attention needed will be to fill the 55# hopper with fuel; inspection of the firepot for
“clinkering” (see operating instructions) and removal of ash buildup as required.


AIR DAMPER ADJUSTMENTS

Each LR-01 is shipped with an air damper adjustment. The air damper control is
located on the front of the pellet stove below the hearth lip located directly centered on
the front door. As site specific operating conditions require, such as fuel, altitude, and
customer usage preferences require, there will be a requirement to adjust the air damper
for more or less combustion air to the unit. To vary the air, the air damper control is
slid in (less air) and out (more air.)