SPECIFICATIONS

FUEL TYPE:

A.P.F.I. residential fuel:

Heat Content: 8200 BTU/lb. min.

Bulk Density: 40 lb. /cubic ft. min.

Moisture Content: 8% max

Ash Content: 1% max

Size: ¼” to 3/8” diameter

1.5”

long

max

Fines: 1% max through 1/8

th

screen


HOPPER SIZE: 55# Hopper Capacity

FLUE SIZE:

3” or 4”

TYPE:

PL double wall vent with stainless steel inner liner


AIR INLET:

1 ½” Sch 40 Black Iron Pipe


AUGER TYPE: Tumac 2 ¼ Auger Pellet Feed System

CONTROLS:

Integrated Feed Rate/Blower Speed Controls


ELECTRICAL: 120 Volts, 2.4 Amp, 60 Hz

MEASUREMENTS:

UNIT BODY HEIGHT

22 ¾”

HEIGHT

ON

PEDESTAL

32

¾”

HEIGHT

ON

LEGS

31

1/4”

UNIT

WIDTH

26”

UNIT

DEPTH

19

3/4”

SHROUD

HEIGHT

29

7/8”

SHROUD

WIDTH

45

7/8”


CLEARANCES:

SIDES

1”

BACK

2”

TOP TO COMBUSTIBLE

3”

TOP TO CEILING

3”


*Combustible Flooring must be covered with non-combustible material extending 6”
(150 mm) from front of unit and 8” (205 mm) from unit on each side. The floor
protection on the sides of the stove only has to extend to the vertical sidewall(s) if the
clearances are less than 8”.