4 peripheral control interface, Peripheral control interface - 7, Cp-rio3-04s functional description – Kontron CP-RIO3-04S User Manual

Page 27

Advertising
background image

CP-RIO3-04S

Functional Description

ID 1036-1669, Rev. 1.0

Page 2 - 7

2.1.4

Peripheral Control Interface

A fan for system cooling and a power supply with power management can be connected to the
CP-RIO3-04S via the peripheral control connector J13.

The following figure illustrates the peripheral control connector J13.

Figure 2-5: Peripheral Control Connector J13

The following table indicates the pinout of the peripheral control connector J13.
Table 2-5: Peripheral Connector J13 Pinout

PIN

SIGNAL

DESCRIPTION

I/O

1

GND

Signal ground

--

2

PWR_5VSTDBY

+5V standby power (optional)

I

3

FAN_SENSE

Fan speed monitor

I

4

VCC5V

Power +5V

O

5

PWM_OUT

Fan speed control via pulse with
modulation signal

O

6

VCC3V3

Power +3.3V

O

7

PWR_SLPS3#

Power supply sleep mode

O

8

GND

Signal ground

--

9

PWR_BTN#

Wake-up / sleep input

I

10

GND

Signal ground

--

Note ...
Pin 5 is an open drain output and has no pull-up resistor on the CP-RIO3-04S.