3 oem event/reading types, Oem event/reading types, Cp6003-sa/ra/rc ipmi firmware – Kontron CP6003-RC IPMI User Manual

Page 29

Advertising
background image

CP6003-SA/RA/RC

IPMI Firmware

ID 1045-5656, Rev. 2.0

Page 29

P R E L I M I N A R Y

7.3

OEM Event/Reading Types

OEM (Kontron) specific sensor types and codes are presented in the following table.

Table 13: OEM Event/Reading Types

OEM

SENSOR

TYPE (CODE)

OEM

EVENT/READING

TYPE (CODE)

DESCRIPTION

Firmware Info 1 (C0h)

70h

Internal Diagnostic Data

Firmware Info 2 (C0h)

71h

Internal Diagnostic Data

Initialization Agent (C2h)

03h
(“digital” Discrete)

Offsets / events:
0: Initialization O.K.
1: Initialization Error

FRU Agent (C5h)

0Ah
(Discrete)

FRU initialization agent, using a standard reading type.

Post Value (C6h)

6Fh
(sensor type specific)

Error is detected if the POST code is != 0 and doesn't
change for a defined amount of time.
In case of no error:
Bits [7:0] = POST code (payload Port 80h)
In case of error:
Bits [15:0] = 4000h
Data2 = POST code, low nibble
Data3 = POST code, high nibble

Firmware Upgrade Manager
(C7h)

6Fh
(sensor type specific)

Offsets / events:
0 : First Boot after upgrade
1 : First Boot after rollback (error)
2 : First Boot after errors (watchdog)
3 : First Boot after manual rollback
4..7 : Reserved
8 : Firmware Watchdog Bite, reset occurred

Board Reset (CFh)

03h
(“digital” Discrete)

Data 2 contains the reset type:
…WARM = 0
…COLD = 1
…FORCED_COLD = 2
…SOFT_RESET = 3
…MAX = 4
Data 3 contains the reset source:
…IPMI_WATCHDOG = 0
…IPMI_COMMAND = 1
…PROC_INT_CHECKSTOP = 2
…PROC_INT_RST = 3
…RESET_BUTTON = 4
…POWER_UP = 5
…LEG_INITIAL_WATCHDOG = 6
…LEG_PROG_WATCHDOG = 7
…SOFTWARE_INITIATED = 8
…SETUP_RESET = 9
…UNKNOWN = 0xFF