AT8902M

Introduction

Page 1 - 8

AT8902M User Guide

General

Mechanical

8U form factor mechanically compliant to PICMG 3.0

Single Slot (6HP)

2 standard mid-size/single width AMC Slots

280 mm x 322 mm (11.024“ x 12.677“)

Weight: 2.1 kg (4.6 Ibs)

Power Requirements

Typical: 65W

Maximum (with 2 AMCs and RTM): 175W

AMCs may consume up to 75W

Operating Voltage: -38 to -72VDC

Temperature

Designed to meet or exceed the following (Characteristics with AMC):

Air Flow: 30 CFM min

Operating: 0°C to +55°C (32°F to 131°F)

Non-operating: -40°C to +70°C (-40°F to 158°F)

Humidity

Designed to meet or exceed the following:

Bellcore GR63, Section 4.1

Operating: 15%-90% (non-condensing) at 55°C (131°F)

Non-Operating: 5%-95% (non-condensing) at 40°C (104°F)

Altitude

Designed to meet or exceed the following:

Operating: 4000 m (13123 ft)

Non-Operating: 15000m (49212 ft)

Vibration

Designed to meet or exceed the following:

Bellcore GR-63, Section 4.4

Operating: 1.0G, 5-500Hz each axis

Non-operating: 0.5G, 5-50Hz; 3.0G, 50-500Hz each axis

Shock

Designed to meet or exceed the following:

DIN/IEC 60068-2-27

Bellcore GR-63, Section 4.3

30G, half-sine 11ms, each axis

Table 1-4: AT8902M Main Specifications (Continued)