4 telecom clock protection switch, 1 telco_switch, 5 fum firmware update manager – Kontron AT8402 Diagnostics Manual User Manual

Page 17: 1 fum_seeprom, Telecom clock protection switch - 9, Telco_switch - 9, Fum firmware update manager - 9, Fum_seeprom - 9, At8402 diagnostics running on the carrier

Advertising
background image

AT8402

Diagnostics running on the Carrier

Page 2 - 9

AT8402 CLI Reference Manual

Description

This test performs read and write accesses in turn to the two IPMC CPLD debug

registers (addresses 0x55 and 0xAA) with changing data patterns (0x00, 0xff, 0xaa and

0x55).

One hundred cycles of writes/reads with all four data patterns to both addresses are

performed, read data is checked for each access to match written data.

Access to the IPMC is performed via KCS interface.

Failure impact

CPLD-00020003 diagnostic code results of failure to access the IPMC through the
KCS interface. The impact is loss of applications running on carrier host processor.
This impacts at least Ethernet functionality and command line interface.

CPLD-00020004 diagnostic code results of failure to access CPLD registers from
IPMC. The impact is failure of the board.

CPLD-00020005 diagnostic code results of a reading of an error condition from
the CPLD. The impact is failure of the board.

2.4

Telecom Clock Protection Switch

NOTE: This part of the diagnostics is not yet implemented. The test procedure all-

ways returns “fail”

2.4.1

TELCO_SWITCH

Clock protection switch test.
Test group:

Diagnostics

Test case:

telco

Test procedure: TELCO_SWITCH
Test host:

Carrier

Test IC:

quickturn

Test mode:

normal

Diagnostic code: TELCO-00030001

Description

Check protection switch readings for consistency.

Failure impact

TELCO-000030001 diagnostic code results of failure of the protection switch.
Impact is failure of telecom clock distribution.

2.5

FUM Firmware Update Manager

2.5.1

FUM_SEEPROM

Firmware update manager SEEPROM read test.
Test group:

Diagnostics

Test case:

fum

Advertising