3 ppc_uart, 4 ppc_ebc, Ppc_uart - 17 – Kontron AT8402 Diagnostics Manual User Manual

Page 25: Ppc_ebc - 17, At8402 diagnostics running on the carrier

Advertising
background image

AT8402

Diagnostics running on the Carrier

Page 2 - 17

AT8402 CLI Reference Manual

2.7.3

PPC_UART

Serial line test.
Test group:

Diagnostics

Test case:

ppc

Test procedure: PPC_UART
Test host:

Carrier

Test IC:

quickturn

Test mode:

normal

Diagnostic code: PPC-00060003

Description

This test checks sending and receiving characters on the serial line by setting the

PPC405 UART into loopback mode. This test is performed automatically during POST

in the case that the environment variable ‘post_en’ has been set. In case of a test failure

an error code is stored in the CPLD postcode warning register.

Parameters: none

Result

The message ‘POST serial passed’ is displayed on the bootloader serial console:

POST serial PASSED

Failure impact

PPC-00060003 diagnostic code results from a failure of the management serial
port. Impact is loss of management access through the serial management port.

2.7.4

PPC_EBC

EBC settings test.
Test group:

Diagnostics

Test case:

ppc

Test procedure: PPC_EBC
Test host:

Carrier

Test IC:

quickturn

Test mode:

normal

Diagnostic code: PPC-00060004

Description

This test checks the settings of the PPC405 external bus controller (EBC). EBC

configuration and status registers are accessed indirectly by reading and writing device

control registers EBC0_CFGADDR (DCR 0x012) and EBC0_CFGDATA (DCR

0x013). Reading and writing device control registers is done using the cpldtool which

provides access to the CPU’s device control registers.

Device access is configured by programming the EBC configuration registers. For each

device, its Peripheral Bank Configuration Register (EBC0_BnCR) and its Peripheral

Bank Access Parameters (EBC0_BnAP) have to be programmed properly.