System specification – Kontron KTHM76-mITX User Manual

Page 13

Advertising
background image

KTQM77 – KTHM76 Users Guide

KTD-N0850-F Page 13

Environmental

Conditions

Operating:
0°C – 60°C operating temperature (forced cooling). It is the customer’s

responsibility to provide sufficient airflow around each of the components to keep

them within allowed temperature range.

10% - 90% relative humidity (non-condensing)


Storage:
-20°C – 70°C; lower limit of storage temperature is defined by specification

restriction of on-board CR2032 battery. Board with battery has been verified for

storage temperature down to -40°C by Kontron.

5% - 95% relative humidity (non-condensing)

Electro Static Discharge (ESD) / Radiated Emissions (EMI):

All Peripheral interfaces intended for connection to external equipment are ESD/

EMI protected.

EN 61000-4-2:2000 ESD Immunity

EN55022:1998 class B Generic Emission Standard.


Safety:

IEC 60950-1: 2005, 2

nd

Edition

UL 60950-1

CSA C22.2 No. 60950-1

Product Category: Information Technology Equipment Including Electrical

Business Equipment

Product Category CCN: NWGQ2, NWGQ8

File number: E194252


Theoretical MTBF:

269.335 / 132.342 hours @ 40ºC / 60ºC for the KTQM77/mITX

>269.335 / >132.342 hours @ 40ºC / 60ºC for the KTHM76/mITX

Restriction of Hazardous Substances (RoHS):

The KTQM77/mITX and KTHM76/mITX are RoHS compliant.

Capacitor utilization:

No Tantalum capacitors on board

Only Japanese brand Solid capacitors rated for 100 ºC used on board

System Specification

Advertising