Mode: 0, Mode: 1, Multifunctional monitor & logger powerlog 6s – ProgressiveRC 6S PowerLog User Manual

Page 12

Advertising
background image


-12-

Multifunctional Monitor & Logger PowerLog 6S

Motor KV Meter

KV as we use it refers to the RPM constant of a motor - it is the number of revolutions per minute that the
motor will turn when 1V (one Volt) is applied with no load attached to the motor.

Mode0: It works at the 2-wire mode, suitable for the KV
measurement of brushless motor.

Mode1
: It works at the 3-wire mode, suitable for the KV
measurement of both brushed and brushless motors.

Regarding the specific operations, please refer to MAIN MENU -> Motor KV Meter P17


Wire Connection Methods of Mode0 and Mode1 as the picture below:










Notes: 1. When measuring KV on the Mode0, the throttle settings of ESC needs to be set at the Max. value.

2. If the tested voltage is lower than 4.5V, PowerLog needs auxiliary power supply.


Data Logging

When in Monitor status, press <▼> button for 3 seconds, after it shows ―Start logging…―, the ―____‖ will be
shown alternatively at the upper right corner of the LCD screen. In this status, the system will transmit the
data to USB port every X seconds( this interval time X can be set by user himself, details you can see Record
Interval Time Settings
in P19), and save these data to the current Log file(See Log File Management in
P15. If 【Logs OFF】, the system will not log file.)
Press <▼> for 3 seconds again, the screen will show ―Stop logging! ― and then exit.

Alarm Remind

If PowerLog detect the alarm events (See Alarm Parameters Settings in P13), it will remind as below:
1. The buzzer beeps every 4 seconds (See Beep Tone Settings in P17,【Alarm Tone】is selected ).
2. The corresponding value and alarm remind show alternatively.

Alarm Remind Information: ―LOW‖ — Lower MIN. limit alarm

OVER‖ — Over MAX. limit alarm

DIFF‖ — Difference alarm

T_OVER‖ — Time over alarm

3. ALM port will output the presetting signal.
ALM port signal information:
ALM output port signal is open collector signal, as showed below.
Please pay attention to the port voltage and current limit when you use(<50V,<500mA)
The following are ALM Output typical application.



Brushless motor

PIN 7

PIN 1

1
2
3
4
5
6

ESC

Battery
(4.5-28V)

+

+

MODE: 0

ALM Output

+

-

Q9

ALM

+

-

VCC

Output

Level Output

R

ALM

+

-

VCC

Output

Relay Output

MODE

00

POLES

07

KV

00953

RPM

05747

U

06.03V

Number of
magnet poles

KV value

Voltage of motor

RPM

Mode

MODE: 1

Brushed motor

PIN 7

PIN 1

1
2
3
4
5
6

ESC

Battery
(4.5-28V)

+

+

+

RPM senor
Hall senor

Advertising