Multifunctional Monitor & Logger PowerLog 6S

2) Cells Monitor
Monitor the input voltage of Multiple Voltage Input Port(J3)






Voltage Sum: the sum voltage of Cell Voltage 1-6

V = Max. Cell Voltage – Min. Cell Voltage

‗‘ is in front of the cell with Max. Cell Voltage, while ‘‘ is
in front of the cell with Min. Cell Voltage.
Setting range
V1-V6: 0.05—28.00V

Difference】Displayed voltage CellVn=Vn–Vn-1 (1≤n≤

6), under the condition V6>V5>V4>V3>V2>V1>0.

Auto Difference】

First sorting by ascending numeric sequence between
V1-V6, then has Va1-Va6, CellVn=Van–Van-1 (1≤n≤6).

Each Voltage】Displayed voltage CellVn=Vn (1≤n≤6).




Press<▲>or<▼>, can shift among the interfaces of current
value, Min. peak value and Max. peak value

Reset peak value
Press<▲>+<▼>, the Min. and Max. peak value will be
replaced to be the current value.

PIN 7

PIN 1

1
2
3
4
5
6

GND

V1
V2

V3
V4
V5

V6

5S

20.63V

V

75mV

1

4.110V

2

4.152V

3

4.087V

4

4.162V

5

4.120V

6

------

Max. Voltage
Difference

Cell Voltage

Voltage Sum

Cell Number

CELLS MODE

⊙Difference

○Auto Differenc
○Each Voltage

<>+<▼>

>3 Seconds

<MENU>

>3 Seconds

5S

20.63

PEAK Min

1

4.100V

2

4.150V

3

4.080V

4

4.160V

5

4.110V

6

------

5S

20.63

PEAK Max

1

4.120V

2

4.172V

3

4.097V

4

4.192V

5

4.130V

6

------