-14-

Multifunctional Monitor & Logger PowerLog 6S

2. Pack Voltage Alarm Settings: Select【Pack Voltage】, press <

> and the screen shows:

PACK VOLT ALARM applies to the T-plug voltage of Watt Monitor
interface.

Setting range

MAX.

0.05V—60.00V MIN.0.00V—59.95V DIFF0.05V—60.00V

3. Monitor Time Over Settings: Select【Timer Over】, press <

> and the screen shows:

TIME OVER ALARM applies to the Timer of Watt Monitor interface.
When monitor time is over the set value, it alarms. T-OVER
Setting range
0-99999 minutes

4. Current Alarm Settings: Select【Current】, press <

> and the screen shows:

CURRENT ALARM applies to the Current of Watt Monitor interface.

Setting range

MAX.

-129.0A—130.0A MIN. -130.0A—129.5A DIFF0.5A—260.0A

5. Power Alarm Settings: Select【Power】, press <

> and the screen shows:

POWER ALARM applies to the Power of Watt Monitor interface.

Setting range

MAX.

-7799W—7800W MIN.-7800W—7799W DIFF1W—15600W

6. Capacity Alarm Settings: Select【Capacity】, press <

> and the screen shows:

CAPACITY ALARM applies to the Capacity of Watt Monitor interface.

When measured capacity is over the set value, it alarms.
Setting range: 100-999900mAh

7. Temperature Alarm Settings: Select【Temperature】, press <

> and the screen shows:

TEMP. ALARM applies to the Temperature of Temperature Monitor
interface.
Setting range

MAX.

-54.9C—125C MIN. -55C—124.9C DIFF 0.1C—180C

8. RPM Alarm Settings: Select【RPM】, press <

> and the screen shows:

RPM ALARM applies to the RPM value of Tachometer Monitor
interface.
Setting range

MAX.

10—99990RMP MIN. 0—99980RMP DIFF10—99990RPM

9. Period Alarm Settings: Select【Period】, press <

> and the screen shows:

PERIOD ALARM applies to the Period of PWM Monitor interface.

Setting range

MAX.

10—999990us MIN.0—999980us DIFF10—999990us

10. Pulse Alarm Settings: Select【Pulse】, press <

> and the screen shows:

PULSE ALARM applies to the +Pulse width of PWM Monitor
interface.

Setting range

MAX.

10—999990us MIN.0—999980us DIFF10—999990us

TIME OVER ALARM
Minutes(0-99999)

120 

CURRENT ALARM

MAX.

130.0A 

MIN.

-130 A 

DIFF

260.0A 

POWER ALARM

MAX.

7800W 

MIN.

-7800W 

DIFF

15600W 

CAPACITY ALARM
(100-999900mAh)

999900 

RPM ALARM

MAX.

99990 RPM

MIN.

0 RPM

DIFF

99990 RPM


PERIOD ALARM

MAX.

999990us 

MIN.

0 us 

DIFF

999990us 

PULSE ALARM

MAX.

999990us 

MIN.

0 us 

DIFF

999990us 

PACK VOLT ALARM

MAX.

60.00V 

MIN.

0.000V 

DIFF

60.00V 

TEMP. ALARM

MAX.

125.0C 

MIN.

-55.0C 

DIFF

180.0C 