Control Panel Components

Installation Instructions

Tools Required

#2 Phillips screwdriver for wall anchors, #1 Phillips screwdriver for cover retaining screw and 3/16” drill if attaching the
mounting base using the included Phillips screws and wall anchors. Only screwdriver for cover retaining screw is required
if you use the Velcro

TM

strips provided.

Step-by Step Installation Procedure

1. Remove all packaging.
2. Remove the cover retaining screw on the front of the unit.
3. Remove the mounting base from the back of the monitoring system control panel by

pressing button on the control panel to release. (See diagram in STEP 3).

4. Install supplied 9 V alkaline battery in battery compartment of control panel.

IMPORTANT - When first installing or changing the battery, disconnect all phone

lines from the alarm control panel. Battery must be alkaline.

5. Choose to maintain or disable the factory pre-set low-temperature (TEMP) alarm function

located inside the main control panel. The alarm is pre-set to ON.

With the control panel removed from the mounting base, locate the dipswitch on the
circuit board. (See photo in STEP 5)

STEP 5

To de-activate the low-temperature alarm, slide the TEMP switch away from the ON
position.

The alarm can be re-activated at any time by sliding the switch to the ON position.

6. Set Pulse/Tone switch on top of monitoring system control panel housing to match your

phone system. (See diagram for STEPS 6 & 7).

7. Set “Call Delay Time” switch on top of control panel housing for the desired delay time the

monitoring system is to wait before making the first outgoing telephone call to indicate an
alarm condition. Choose either 5 or 30 minutes. (See diagram for STEPS 6 & 7).

8. Locate a suitable location for the mounting base of the monitoring system control panel,

preferably within three feet of both an accessible telephone jack and a 120-Volt electrical
outlet. If installing beyond three feet from the telephone jack, you will need to purchase a
longer telephone cord. Install mounting base with screws (included) or Velcro strips
(included). Use anchors if installing into drywall or plaster. For appearance, adjust as level
as possible. (See diagram for STEP 8.)

9. Replace the monitoring system control panel on its mounting base by fitting then snapping

into place. Insert the cover screw in the hole to the right of the on/off switch and tighten,
securing the control panel to the base.

10. Connect telephone cord to the "To Wall Phone Jack" on the bottom of the control panel

housing (3 foot telephone cord is included)

11. Connect answering machine, telephone, or fax

machine to the "To Phone" jack on the bottom of
the control panel housing using an existing
telephone cord.

12. Plug AC adapter into a 120-Volt electrical outlet.

Insert the plug on the AC adapter into the
“Power Jack” on the bottom of the control panel
housing.

13. If using the remote water sensor, plug the

telephone line from the water sensor into the
"Water Sensor Jack". Additional telephone line
up to 100 feet (purchased separately) can be
patched between the control panel and the
Water Sensor. Do not exceed 100 feet.