Programming the Outgoing “Call-To” Telephone Numbers

Now that you have installed your monitoring system, you are ready to
program the outgoing telephone numbers to be called during an
alarm condition—such as your cell phone, your cabin phone, your
primary residence phone or a neighbor’s phone. Before you begin
the simple step-by-step programming procedure below, check and
confirm that:

The ON / OFF switch on the control panel is in the ON position.

The monitoring system control panel is properly connected to the
wall adapter and phone lines, and that the Water Sensor is
properly connected for Model THP201 only.

• If the monitoring system has been idle for a long period, install a

fresh 9V alkaline battery. The installed battery will discharge
when the monitoring system has no AC power even when the
monitoring system is turned off.

To program the first outgoing telephone number:

1. Press and hold the “1” key on the keypad for 10 seconds until

the “system armed” green light blinks two times and then stays
off.

2. Release the “1” key. Using the keypad, enter the first outgoing telephone number (maximum of 12 digits).
3. Press and hold the “#” key for 10 seconds until the green light blinks twice and then stays lit.
4. The green light should stay lit to indicate the number was properly programmed and retained in memory. If not,

repeat steps 1 through 3.

Note: Programming over a number already in memory will replace the number in memory.

Important! Do not program emergency response phone numbers (local police or fire
departments, “911”, etc.) into the monitoring system. Do not program phone numbers to
a location where there is no one to answer the phone, or where the person answering has
not been instructed on how to respond to the alarm call.

Important! This monitoring system will not accept 9-pause outgoing numbers.

To program the second and third outgoing telephone numbers:

Repeat steps 1 through 4 above except press the “2” key to designate the second outgoing number, and the “3” key to
designate the third outgoing number.

Outgoing Number Calling Sequence

When an alarm condition is first detected, the monitoring system will call the first programmed outgoing telephone number
that it locates. It will always scan in sequence “call-to” location 1, location 2, and location 3. If a telephone number is not in
location 1, but does exist in location 2, then the location 2 programmed telephone number will be the first telephone
number the monitoring system will call with the alarm message. It is not necessary to program all three telephone numbers
for the monitoring system to work properly.

Important! This monitoring system cannot call out on an Internet phone line during a
power outage because the Internet phone system needs power to operate.

Reprogramming or Clearing All Programmed Telephone Numbers

Programming over the number in memory will replace that number. If you find that you need to clear the telephone
numbers that are stored in memory, unplug the monitoring system control panel from the wall adapter and remove the 9V
battery for 30 seconds or more. The memory will now be erased and the reprogramming sequence can be restarted.

Programming Sequence Summary

Program 1

st

phone number

1. Press the “1” key for 10 seconds until green light blinks twice and then stays off.

2. Enter a maximum of 12 digits for a telephone number

3. Press the # key for 10 seconds until the green light blinks twice and then stays lit.

4. If the green light does not stay lit, repeat the programming sequence for this number

Program 2

nd

phone number

1. Press the “2” key for 10 seconds until green light blinks twice and then stays off.

2. Enter a maximum of 12 digits for a telephone number

3. Press the # key for 10 seconds until the green light blinks twice and then stays lit.

4. If the green light does not stay lit, repeat the programming sequence for this number

Program 3

rd

phone number

1. Press the “3” key for 10 seconds until green light blinks twice and then stays off.

2. Enter a maximum of 12 digits for a telephone number

3. Press the # key for 10 seconds until the green light blinks twice and then stays lit.

4. If the green light does not stay lit, repeat the programming sequence for this number

NOTE: An abbreviated Programming Sequence Summary is also located on the pullout instruction tab on the side
of the control panel housing.