4 indicator operations, 1 toggle gross/net mode, 2 toggle units – Rice Lake 880 Performance Series Indicator/Controller Operators Manual User Manual

Page 10: 3 zero scale, 4 acquire tare, 5 remove stored tare value, Toggle gross/net mode, Toggle units, Zero scale, Acquire tare

Advertising
background image

Introduction

6

1.4

Indicator Operations

Basic 880 operations are summarized below:

1.4.1

Toggle Gross/Net Mode

1. Press

to toggle the display mode between gross and net.

Net mode is available when a tare value has been entered or acquired,
(NET = GROSS minus TARE). If tare has not been entered or acquired, the
display remains in gross mode. LEDs next to Gross or Net indicates the
current mode.

1.4.2

Toggle Units

1. Press

to switch between primary and secondary units. The current

units LED will be lit.

1.4.3

Zero Scale

1. In gross mode, remove all weight from the scale and wait for the

LED

to light.

2. Press

. The

LED lights to indicate the scale is zeroed.

The scale must be stable and within the configured zero range, for the
scale to be zeroed. If the scale cannot be zeroed, NOZERO will display.

1.4.4

Acquire Tare

1. Place container on scale and wait for the

LED to light.

2. Press

to acquire the tare weight of the container. Net weight is

displayed and the T LED lights to show the tare value was entered.

1.4.5

Remove Stored Tare Value

1. Remove all weight from the scale and wait for the

LED to light.

2. The display should read zero and the

LED should be lit, zero the

scale if needed.

3. Press

(or, in OIML mode

). Display shifts to gross weight

and the Gross LED is lit.

If keyed tare is allowed, press

to open the keyed tare prompt. To

clear the tare press

again.

GROSS

NET

B/N

Note

UNITS

ZERO

0

Note

TARE

0

TARE

ZERO

Note

TARE

TARE