2 edp command configuration, 3 front panel configuration, Edp command configuration – Rice Lake 880 Performance Series Indicator/Controller Operators Manual User Manual

Page 16: Front panel configuration

Advertising
background image

Configuration 12

2.1.2

EDP Command Configuration

The EDP command set can be used to configure the 880 indicator using either a

personal computer or terminal. Like Revolution, EDP command configuration sends

commands to the indicator EDP port; unlike Revolution, EDP commands can be sent

using any external device capable of sending ASCII characters over a serial

connection.
EDP commands duplicate the functions available using the indicator front panel and

provide some functions not otherwise available. EDP commands can be used to

simulate pressing front panel keys, to configure the indicator, or to dump lists of

parameter settings. See the Technical Service manual for more information about

using the EDP command set.

2.1.3

Front Panel Configuration

The 880 indicator can be configured using a series of menus accessed through the

indicator front panel when the indicator is in setup mode. Table 2-1 summarizes the

functions of each of the main menus.

Figure 2-2. 880 Menu Layout

Menu

Menu Function

AUDIT

Audit Trail

Displays the legally relevant (LR) firmware version,
configuration count and calibration count.

SETUP

Setup

T&D

Time and Date

View and change time and date.

ACCUM

Accumulator

Displays the current accumulator value.

SETPTS

Setpoints

Configure setpoints.

TARE

Tare

Tare function. Enables or disables push-button and
keyed tare

Table 2-1. 880 Menu Summary

000000

000000

ACCUM

Displayed only

if turned on in

Scale Menu

AUDIT

TARE

SETPTS

T & D

ACCUM

SETUP

000000

DATE

TIME

No Access
unless the

jumper is

installed

VIEW

CLR Y?

000000

See

Figure 2-7

See

Figure 2-6

See

Figure 2-18

Advertising