Specifications – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - Analog Output Card Option Installation Manual User Manual

Page 6

Advertising
background image

Specifications

Resolution:

16-bit, monotonicity

Linearity

±0.01% of full scale input, Drift +/-10ppm/degree C Maximum

Current Output

0–20 mA or 4–20 mA

Maximum Load Resistance 667

Voltage Output

0–10 VDC

Minimum Load Resistance 1 K

Input Protection

Short circuit protection, 600W transient voltage suppression

Protection for ESD, EFT (electrical fast transients), tertiary lightning, and system-generated transients per
IEC 60001-4-2, 60001-4-4, and 60001-4-5; European Standards EN50082 and EN61000-4