6 option cards, Digital i/o serial ports – Rice Lake 920i FlexWeigh Systems - 101 User Manual

Page 10

Advertising
background image

6

System 101 Basic Filler

2.6

Option Cards

Table 2-2 list the available option card that are used in the System 101. The single channel A/D card can be
installed in slot 1 and the 24 channel I/O card in slot 2.

Digital I/O

Serial Ports

Slot

Type

1

Single Channel A/D Card

2

24 Channel I/O Card

Table 2-2. Option Card Locations

Slot

Bit

Type

Function

0

1

Programmability

E-Stop

0

2

Start

0

3

Resume

0

4

Reset

0

5-6

Off

Currently not used

2

1

Output

Fast Fill

2

2

Slow Fill

2

3

Fill Complete

2

4

Zero Tolerance

2

5-24

Off

Currently not used

Table 2-3. Digital I/O Assignments

Port

Type

Description

Setup

1

CMD

Currently not used

9600 baud
8 bit
None
2

2

CMD/KEYBOARD

iRev downloads/operator input

115200
8 bit
None
2

3

CMD

Audit trail printer

9600 baud
8 bit
None
2

4

CMD

Currently not used

9600 baud
8 bit
None
2

Table 2-4. Serial Port Setup

Advertising