920i

Analog Input Card with Thermocouple Input Installation Instructions

Absolute Max. Input Signal

1

J1 & J2

Volts –11 to +15V, Input +/– 20.4 mA

J3

–0.3V to 5V w/respect to (-T/mV) input


Input Impedance

Typical
J1 & J2

+/–10 >27k

Ω 0-20mA 249Ω (measurement shunt)

J3

+/–100mV >100K

Ω

Input Protection

J1 & J2

15V, 600Watts (suppression diodes)

Sample Rates

Selectable

10, 50, 60, or 250Hz

Power Consumption

200mW, 30mA

Thermocouple Input Types

E, J, K, N, T
Thermocouple Temperature Ranges
E

-454 to 1832°F

J

-346 to 2192°F

K

-454 to 2501.6°F

N

-454 to 2372°F

T

-454 to 752°F

Accuracy +/– 1° C

Temperature Input

Internal Temperature Sensor

1. Absolute maximum input ratings are those values beyond which the life of the input card may be impaired.