The WLAN configuration port uses the following settings:

Baud Rate - 9600

8 Bits

No Parity

1 Stop Bit

No Flow Control

Make the changes and press

OK

to save those changes.

5. Reset the WLAN option card by pressing the manual reset button, and immediately upon release enter

three lowercase

x

characters (

xxx

) at the same time. The manual reset button location is shown in Figure 8.

Figure 8. Manual Reset Button Location on WLAN Option Card

NOTE: The easiest way to connect is to hold down the x key on the PC’s keyboard until the manual reset button is released and the
PC screen displays the MAC address and software version as shown in Figure 9. This must be done within three seconds of
resetting the WLAN option.

Upon a successful connection, the following information is displayed.

Figure 9. Display Information for Setup Mode

6. To enter Setup Mode, press

Enter

within five seconds. Note that the connection will fail if

Enter

is not

pressed within the five second time limit. The configuration settings display, followed by the setup menu

options. If this happens, repeat Step 5.

7. Select an option on the menu by entering the number of the option in

Your Choice?

field and press

Enter

. In

Manual Reset Button