10 batch operations, In/out softkeys – Rice Lake Counterpart Configurable Counting Indicator - Installation and Operation Manual V2.3 - Rev C User Manual

Page 75

Advertising
background image

Scale Operations

69

5.10 Batch Operations

Softkeys can be configured to allow the operator control of batch operations from the Counterpart front panel (see
Figure 5-4). Softkeys can be configured using serial commands, or the FEATURE menu.

Figure 5-4. Counterpart Batch Operation Screenshot

Batching Switch
The batching switch option, PN 19369, comes as a complete unit in an FRP enclosure, with legend plate, locking
stop switch (mushroom button), and a run/start/abort 3-way switch.

Both switches are wired into the Counterpart’s digital I/O terminal strip as shown in Figure 5-6 on page 70. Each
switch uses a separate digital input.

Once cables and switch have been connected to Counterpart, use the menu button to place Counterpart in setup
mode. Use the DIG I/O menu to configure the digital input and output functions.

Figure 5-5. Batching Switch

When configuration is complete, exit setup mode. Initialize the batch by turning the 3-way switch to Abort, then
unlock the STOP button (the STOP button must be in the OUT position to allow the batch process to run). The
batching switch is now ready to use.

If no digital input is assigned to BATRUN, batching proceeds as if BATRUN were always on; the batch will
start the 3-way switch is turned to RUN, but the STOP mushroom button will not function

Parameter

Description

Setponit

Display or change assigned setpoints

Batch Start

Starts the batch process

Batch Reset

Steps and resets an active batch to the beginning of the process.

Batch Stop

Stops an active batch and turns off all associated digital outputs.

Table 5-2. Batching Softkeys

WARNING

Advertising