2 model designations, 3 operating requirements, 2 model designations 1.3 operating requirements – Rice Lake Washdown User Manual

Page 7

Advertising
background image

Introduction

3

1.2

Model Designations

The model identification plate is located on the side of the frame next to the slide-out junction box tray. Include
both model number and serial number when ordering replacement parts.

The following model designations are used to describe the different scale versions:

HP — Mild steel, high precision, NTEP-certified as “legal-for-trade” and FM-approved load cells.

HP-H — 20K- and 30K-lb capacity HP models.

SS — Non-washdown stainless steel, NTEP-certified model, for dry chemical and corrosive environments.

HE — Washdown stainless steel, external mounted, NTEP-certified model with hermetically-sealed load
cells and NEMA 4X J-box for hostile environments.

1.3

Operating Requirements

Electrical Grounding

For systems where the scale is connected to a 115 VAC circuit, the indicator must be directly connected to an earth
ground with a ground interface cable of no more than 3

 resistance throughout its length.

Load Cell Excitation

Rated Excitation: 10 VDC, Maximum Excitation: 15 VDC

Grade Level Requirements

The supporting surface for the four feet of the scale must be level within

1

/

4

in. of horizontal.

Safe Static Overloading Capacity

Maximum: 150% of scale capacity

Nominal Scale Height

2K–10K lb (1000–5000 Kg) models: 3.5 in (89 mm)

20K lb (10000 Kg) models: 4.0 in (102 mm)

30K lb (15000 Kg) models: 5.0 in (127 mm)

Advertising