0 installation, 1 overview, 2 site preparation – Rice Lake Washdown User Manual

Page 8: Installation, 1 overview 2.2 site preparation

Advertising
background image

4

RoughDeck Low Profile Floor Scale

2.0

Installation

2.1

Overview

Standard installation of the RoughDeck floor scale consists of the following steps:

1. Select a site

2. Check levelness and smoothness of site

3. Unpack scale

4. Adjust the four feet on the scale

5. Install mounting plates to the floor

6. Connect cable from junction box to indicator

7.

Calibrate the unit

Pit installations and access ramps are described in Section 2.6 and Section 2.7.

2.2

Site Preparation

Location

Important

The scale must not be loaded beyond its capacity, even momentarily.

Select a site where overweight loads can maneuver easily without crossing the platform.

Avoid areas where damage could occur from side impacts of wheels or forklift tines.

Avoid areas where falling objects could cause shock damage.

Avoid areas where water may damage a scale not meant for a washdown environment.

The scale must be level within 1/4 inch. Choose a site where the floor is level to this standard to avoid
excessive shimming. The floor may require modification if unable to select and area up to standard.

Cabling

The interface cable between the scale and the indicator must be protected against crushing, cutting, or moisture
damage.

Important

If the chosen site has such potential dangers, some method of protection, such as running the
cable in conduit, will be required.