Wiring diagram - load cells in hazardous areas – Rice Lake Load Cells - Wiring for Hazardous Environments User Manual

Page 24

Advertising
background image

Control Drawing 66021

21

SCALE

TREA

TMENT

ANGLE

3 PLC

2 PLC

TOL.

DECIMAL

DRAWING TOLERANCES

TITLE

SHEET OF

DWG NO

THIS DRAWING AND ALL INFORMA

TION CONT

AINED HEREIN IS AND REMAINS

THE PROPER

TY OF RICE LAKE WEIGHING SYSTEMS INC. AND IS CONFIDENTIAL.

IT IS SUBMITTED AND MA

Y BE USED ONL

Y IN CONNECTION WITH RICE LAKE

WEIGHING SYSTEMS' PROPOSAL AND/OR ITS CUSTOMERS' ORDERS. IT SHALL NOT BE

DISCLOSED TO OTHERS OR COPIED WITHOUT RICE LAKE WEIGHING SYSTEMS' SPECIFIC

WRITTEN CONSENT AND SHALL BE IMMEDIA

TEL

Y RETURNED UPON REQUEST

.

REVISION

REVISIONS

REV

REFERENCE

INIT

DA

TE

ALL THREADS TO BE CLASS 2

UNLESS OTHER

WISE SPECIFIED

ALL DIMENSIONS APPLICABLE AFTER TREA

TMENT

UNLESS OTHER

WISE SPECIFIED

DO NOT SCALE

DRAWING

SURF

ACE

FINISH

MA

TERIAL

THIRD ANGLE PROJECTION

UNITS TO BE INCHES

FOR RL

WS

USE ONL

Y

RICE LAKE WEIGHING SYSTEMS

MFG.ENG.

DR.BY

APPROVED

DES.ENG.

APPROVED

CKD.

WIRING DIAGRAM -

LOAD CELLS IN HAZARDOUS AREAS

66021

1:1

19

---

---

---

---

---

NONE

NEW

SLJ 9/15/00

ECO10664: ADDED RLHSS, RLSB250, RLSSB TO SHEETS 2, 5, 6 & 8; DELETED RL8C2P1SS

FROM SHEETS 2, 5, 6 & 8; DELETED RL75060S FROM SHEET 2; RL70000A W

A

S

SLJ

RL70000 ON SHEETS 7 & 9; RL75223A W

AS RL75223 ON SHEET 9; RL75016WHE W

A

S

RL75016HE ON SHEETS 3 & 4; ADDED RL75016WHE TO SHEETS 7 & 9; DWG NO. W

AS 460255.

NEW

9/15/00

11.

10.

13. SEE SHEET 2 FOR NO BARRIER APPLICA

TION.

12. EACH SHEET LISTS THE LOAD CELL MODEL NUMBERS TO WHICH IT APPLIES.

BARRIER BOXES : BBX-XX SERIES.

JUNCTION BOXES : EL604ST

A, EL604STR, EL604ET

A, EL210, EL211A, AND JB808.

RICE LAKE WEIGHING SYSTEMS MANUF

ACTURES JUNCTION BOXES AND BARRIER BOXES.

6. R. ST

AHL BARRIERS ARE MANUF

ACTURED A

T

150A NEW BOSTON ST

. WOBURN, MA. 01801.

8. INST

ALL PER ANSI/ISA - RP12.6.

7. SHT 6, 7, 8 & 9 REPRESENTS ST

AHL BARRIER SPECIFICA

TIONS.

9. 700 OHM BRIDGES ARE TYPICAL V

ALUES, BRIDGE RESIST

ANCE MA

Y BE = OR > 700 OHMS.

350 OHM BRIDGES ARE TYPICAL V

ALUES, BRIDGE RESIST

ANCE MA

Y BE = OR > 350 OHMS.

IN THE LOAD CELL EXCIT

A

TION CIRCUIT

.

DUE TO THE SERIES RESIST

ANCE OF THE SAFETY BARRIERS

NOTE:

1. DRAWING REVISIONS MUST BE APPROVED BY F

ACTOR

Y MUTUAL PRIOR TO RELEASE.

2. ELECTRICAL EQUIPMENT CONNECTED TO BARRIER INPUTS

SHOULD NOT USE OR GENERA

TE MORE THAN 250 VOL

TS RMS.

3. A REDUCTION OF THE LOAD CELL SIGNAL OUTPUT WILL OCCUR,

REP

. IN USA : MTL INC., 8576 WELLINGTON ROAD, MANASSAS, V

A. 22110.

5. SHT 3, 4 & 5 REPRESENTS MTL BARRIER SPECIFICA

TIONS.

4. MTL BARRIERS ARE MANUF

ACTURED IN ENGLAND;

0