32 load cell wiring for hazardous environments, Control dra wing, load cell – Rice Lake Load Cells - Wiring for Hazardous Environments User Manual

Page 35

Advertising
background image

32

Load Cell Wiring for Hazardous Environments

LOAD CELL

SEE NOTE 3

VMAX = 12V C1=0

IMAX = 100MA LI=0

VMAX = 12V C1=0

VMAX = 12V C1=0

VMAX = 12V C1=0

VMAX = 12V C1=0

VMAX = 12V C1=0

IMAX = 100MA LI=0

IMAX = 100MA LI=0

IMAX = 100MA LI=0

IMAX = 100MA LI=0

IMAX = 100MA LI=0

+ EXCIT

A

TION

+ SENSING

+ SIGNAL

- SIGNAL

- SENSING

- EXCIT

A

TION

{FM APPROVED BARRIERS}\P{SEE NOTE 5}

{GROUND BUSS}

(TERMINA

TE PER BARRIER}

{MANUF

ACTURERS RECOMMENDA

TION)}

HAZARDOUS AREA

CLASS I, II, III, DIVISION 1

GROUP A, B, C, D, E, F

, G

NON HAZARDOUS AREA

NOTE:

1. INST

ALLA

TION WIRING TO BE IN ACCORDANCE WITH ANSI-ISARP 12.6

(INST

ALLA

TION OF INTRINSICALL

Y SAFE INSTRUMENT SYSTEMS IN

CLASS I, II, III HAZARDOUS AREAS).

2. ELECTRICAL EQUIPMENT CONNECTED TO BARRIERS SHOULD NOT USE OR

GENERA

TE MORE THAN 250 VOL

TS.

3. THE FOLLOWING LOAD CELL MODULES ARE APPROVED FOR USE IN CLASS

I, II, III DIVISION 1 GROUPS A, B, C, D, E, F

, AND G.

RL1380

4. ASSOCIA

TED APP

ARA

TUS MUST HA

VE FM ENTITY APPROV

AL.

5. ONL

Y SINGLE CHANNEL BARRIERS OF SAME POLARITY MA

Y BE USED.

6. VOC. AND Isc ON INDIVIDUAL BARRIERS MUST NOT EXCEED V

ALUES SHOWN.

7. NO REVISIONS ARE TO BE MADE TO THIS DOCUMENT WITHOUT PRIOR WRITTEN

APPROV

AL OF THE F

ACTOR

Y MUTUAL RESEARCH COMP

ANY

.

REVISIONS

REV

REFERENCE

INIT

DA

TE

SCALE

TREA

TMENT

ANGLE

3 PLC

2 PLC

TOL.

DECIMAL

DRAWING TOLERANCES

TITLE

SHEET OF

DWG NO

THIS DRAWING AND ALL INFORMA

TION CONT

AINED HEREIN IS AND REMAINS

THE PROPER

TY OF RICE LAKE WEIGHING SYSTEMS INC. AND IS CONFIDENTIAL.

IT IS SUBMITTED AND MA

Y BE USED ONL

Y IN CONNECTION WITH RICE LAKE

WEIGHING SYSTEMS' PROPOSAL AND/OR ITS CUSTOMERS' ORDERS. IT SHALL NOT BE

DISCLOSED TO OTHERS OR COPIED WITHOUT RICE LAKE WEIGHING SYSTEMS' SPECIFIC

WRITTEN CONSENT AND SHALL BE IMMEDIA

TEL

Y RETURNED UPON REQUEST

.

REVISION

ALL THREADS TO BE CLASS 2

UNLESS OTHER

WISE SPECIFIED

ALL DIMENSIONS APPLICABLE AFTER TREA

TMENT

UNLESS OTHER

WISE SPECIFIED

DO NOT SCALE

DRA

W

ING

SURF

ACE

FINISH

MA

TERIAL

THIRD ANGLE PROJECTION

UNITS TO BE INCHES

FOR RL

WS

USE ONL

Y

RICE LAKE WEIGHING SYSTEMS

MFG.ENG.

DR.BY

APPROVED

DES.ENG.

APPROVED

CKD.

CONTROL DRA

WING, LOAD CELL

66147

1:1

22

---

---

---

---

N/A

NONE

A

W

AH 11/10/00

DFH 11/10/00

0

Advertising