Control Drawing 53414

39

RL20000B

RL30000

RL90000

RL20001-T10

RL35023-N5

RL30000W

RL35023SS

RL1521

RL35023

-

+

-

+

-

+

SCALE

TREA

TMENT

ANGLE

3 PLC

2 PLC

TOL.

DECIMAL

DRAWING TOLERANCES

TITLE

SHEET OF

DWG NO

THIS DRAWING AND ALL INFORMA

TION CONT

AINED HEREIN IS AND REMAINS

THE PROPER

TY OF RICE LAKE WEIGHING SYSTEMS INC. AND IS CONFIDENTIAL.

IT IS SUBMITTED AND MA

Y BE USED ONL

Y IN CONNECTION WITH RICE LAKE

WEIGHING SYSTEMS' PROPOSAL AND/OR ITS CUSTOMERS' ORDERS. IT SHALL NOT BE

DISCLOSED TO OTHERS OR COPIED WITHOUT RICE LAKE WEIGHING SYSTEMS' SPECIFIC

WRITTEN CONSENT AND SHALL BE IMMEDIA

TEL

Y RETURNED UPON REQUEST

.

REVISION

REVISIONS

REV

REFERENCE

INIT

DA

TE

ALL THREADS TO BE CLASS 2

UNLESS OTHER

WISE SPECIFIED

ALL DIMENSIONS APPLICABLE AFTER TREA

TMENT

UNLESS OTHER

WISE SPECIFIED

DO NOT SCALE

DRAWING

SURF

ACE

FINISH

MA

TERIAL

THIRD ANGLE PROJECTION

UNITS TO BE INCHES

FOR RL

WS

USE ONL

Y

RICE LAKE WEIGHING SYSTEMS

MFG.ENG.

DR.BY

APPROVED

DES.ENG.

APPROVED

CKD.

WIRING DIAGRAM

LOAD CELLS IN HAZARDOUS AREAS

53414

1:1

69

---

---

---

---

SEE NOTES

NONE

C

SBD 10/28/99

0

OPTIONAL

JUNCTION

FOR 10V DC MAX. SUPPL

Y & 350 OHM CELLS

C) MAXIMUM ALLOW

ABLE CABLE LENGTH IS 375 FEET

.

B) MAXIMUM CABLE INDUCT

ANCE IS 0.075mH.

NOTE: A) MAXIMUM CABLE CAP

ACIT

ANCE IS 0.346uF

.

VOL

T

AGE A

T

LOAD CELL

(10V EXCIT

A

TION)

NUMBER OF

LOAD CELLS

3

4

1

2

5.64V

5.00V

6.51V

7.65V

BOX

DRAWING REVISIONS MUST BE APPROVED

BY F

ACTOR

Y MUTUAL PRIOR TO RELEASE.

(1 TO 4 CELLS)

BARRIER

BOX

OPTIONAL

-EXC

+EXC

INTRINSICALL

Y SAFE - CLASS I,II,III, DIVISION 1, GROUPS A-G

+SEN

-SEN

+OUT

-OUT

350 OHM

LOAD CELL

BRIDGE

350 OHM LOAD CELL

MODEL NUMBERS:

HAZARDOUS LOCA

TION

SENSE (RECOMMENDED)

NON - HAZARDOUS LOCA

TION

9002/22-093-040-00

9001/02-016-015-10

4

3

3

9001/01-168-020-10

9001/02-016-150-11

3

3

9001/01-158-390-10

3

REMOTE

OUTPUT

SIGNAL, mV

EXCIT

A

TION SUPPL

Y

(10VDC MAX.)

2

1

1

1

1

LOAD CELL

1

11