LoadRunner™ Series Installation & Service Manual

3.3

Power Cable Connection to Battery

Brown wire to positive

Fuse

Blue wire to negative

Figure 3-8. Power Connection to Battery

1. Wire the fuse (5A) to the brown wire.

2. Connect the power cable to the battery.

- Brown wire connects to positive terminal.

- Blue wire connects to ground.

3.4

Hydraulic Pressure Transducer

The hydraulic pressure transducer should be installed at the hydraulic control valve.

Tee Fitting

Reducing Fitting

Transducer

Hydraulic Valve

Figure 3-9. Install Hydraulic Pressure Transducer

1. Remove the hose where the transducer is to be installed.

2. Install a tee fitting to connect the hose to the hydraulic valve.

3. Insert a reducer if required (9/16

” straight thread with O-ring is required to fit the Rice Lake pressure

transducer) to the opening in the tee where the transducer is to be installed.

4. Run the cable along the frame to the cable access hole in the cab. Wire-tie the cable to the frame.

Important

Note

Allow for slack when fitting and securing hydraulic hose lines as these move during normal operation.

Plan a transducer cabling route that has little or no risk of pinching, stretching or melting the cables.

Use split loom on all exposed cable to protect in areas where damage could be an issue.