Rice Lake MSI4300 PortaWeigh Plus Crane Scale 5 Key User Manual

Page 17

Advertising
background image

M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L

MSI-4300 Porta-Weigh Plus/5 Key

User Guide Page 17

1) Enable Calibration by pushing the key behind the

seal port.

2) Use the SELECT (NET/GROSS) key to scroll to

the “HI SETPT” (or “LO SETPT”) message. Push
ENTER (TEST).

3) The message display reads “HI VALUE.” Push

ENTER.

4) The most significant digit flashes. The display reads

“INPUT WT.” Push the SELECT key until the first
digit of the desired weight value is displayed. Push
ENTER. (The CLEAR (ZERO) key can be used to
change an entry if necessary). Note: To enter 100
kgs on a 10,000 kg scale, the first two digits should
be entered as zeros (00100).

5) The next most significant digit flashes. Use the

SELECT key and the ENTER key to finish out the
entry. Note: With the IR remote, the value can be
entered directly.

6) After the entire Hi Set Point is entered the display

will step to “MODE.” Push ENTER. The first se-
lection is “DISABLED.” This mode allows the
user to program a setpoint without the setpoint
actually operating. To enable the setpoint, push
SELECT until either the “GROSS” mode or the
“NETGROSS” mode is selected. In the “GROSS”
mode the setpoint will operate at the value set
based on Gross Weight regardless of any tare value
being subtracted. If this is the desired setpoint op-
eration mode push ENTER. If the setpoint should
operate relative to a tared weight the “NETGROSS”
mode should be used. Use the SELECT key to
change from “GROSS” to “NETGROSS” and then
push ENTER. In this mode the setpoint will oper-
ate at the value which represents either a Gross
weight or a Net weight.

7) The next selection is the Setpoint “RESPONSE”

— what the scale should do when a setpoint value
is reached. Push ENTER. There are now three se-
lections: The “NORMAL” response turns on the
internal MOSFET which is connected to a user-
supplied alert device such as a siren or strobe light.
Use the SELECT key to change the response to

INDIVIDUAL DIGIT FLASHES EVERY

TIME SELECT KEY IS PUSHED.

Advertising