Rice Lake Wheelchair Scale Technical Manual
8.2.2
Maintenance Protocol
Table 8-4 lists the maintenance protocol commands.
8.3
USB Connection
The Rice Lake Wheelchair Scale has the capability of connecting to a PC using a USB connection and a USB
cable (not included). That connection location is shown in Figure 8-5.
Figure 8-5. USB Connection Port
Connecting software and downloads should be addressed by your IT department and can vary depending on what
type of computer platform you’re using. Basic information on USB driver installation using Windows
®
Driver download. Click on
Download
to open and download the driver to your computer.
1. The graphic below shows the window that pops up when the USB cable is connected to the indicator and
the scale is turned on.
Command
Definition
R
Reboot
V
Firmware ID + development version
W
Current weight
A
Current AD
Z
Zero the scale
F
Show flash values (used for the first flash process)
L
USB On/Off (not available on USB communication
Table 8-4. Maintenance Protocol Commands
USB Connection
RS-232 connection
Load Cell Connection