46

Slip Control

<ESC>

<SI>

n

1B

0F

n

Setting slip sensor
Sets the slip printer TOF/BOF sensor according to the value of n.

TOF Sensor

BOF Sensor

n = 00, “0” :

Valid

Valid

01, “1” :

Valid

Invalid

02, “2” :

Invalid

Valid

03, “3” :

Invalid

Invalid

The default value is n="0" when memory switch 5-2 = 0 (set when
the unit is shipped from the factory,) and n="3" when memory switch
5-2 = 1.

<ESC>

<FF>

n

1B

0C

n

Slip function
After printing the data in the line buffer, operates the slip printer
according to the value of n.

n = 00, “0” :

Operates the clamp

01, “1” :

Releases the paper

02, “2” :

Releases the paper and waits until it is removed

03, “3” :

Feeds the paper backward (backfeed) until it
moves past the TOF sensor, then releases the
paper. (See NOTE below.)

04, “4” :

Feeds the paper into the printer (operational feed)
until it moves past the BOF sensor, then releases
the paper.

05, “5” :

Feeds the paper according to the direction and
length set by <ESC> <VT> m n (the paper is not
released)

(NOTE) When the slip paper is attached to duplicates, a paper jam

may occur if the paper is always fed backward. Therefore,
the paper should not be ejected with n=3. To feed slip paper
attached to duplicates backward, use <ESC> <VT> to set
the eject length to about half of the paper length, then eject
the paper using <ESC> <FF> 5.

CODE

HEX

FUNCTION

CODE

HEX

FUNCTION

Advertising