10
RD-300/RD-232 Installation & Operation Manual
2.4.4
Configuring the RD-300/RD-232
The RD-300/RD-232 must be properly configured. To do this, you must know:
•
Which indicator?
•
What Baud Rate?
•
How does the display handle a loss of signal?
•
Are you going to use the universal mode?
•
Do you want to retransmit data in Condec format or in the format it was received?
Once this information is known, it is entered through SW1 and SW2, DIP switches on the CPU board. (See
Figure 2-7, and table below).
Figure 2-7. DIP Switch Settings
Meter Number
Receiver
SW1-1
SW1-2
SW1-3
SW1-4
0
Universal
On
On
On
On
1
IQ plus, Condec
On
On
On
Off
2
Toledo
On
On
Off
On
3
Flex-Weigh
On
On
Off
Off
4
Analogic
On
Off
On
On
5
Fairbanks
On
Off
On
Off
6
Cardinal
On
Off
Off
On
7
Masstron
On
Off
Off
Off
8
AND
Off
On
On
On
9
Weigh-tronix
Off
On
On
Off
10
Spare
Off
On
Off
On
11
Doran
Off
On
Off
Off
12
Sartorious
Off
Off
On
On
13
GSE
Off
Off
On
Off
14
Hardy
Off
Off
Off
On
15
Spare
Off
Off
Off
Off