Rice Lake RD-300 Remote Display User Manual

Page 8

Advertising
background image

6

RD-300/RD-232 Installation & Operation Manual

LK$="

KG

"

end if

DO L

I

F

KEN(SVAL$)<7

then

SVAL$= " " +SVAL$

else

exit

DO

end if

LOOP

DISPSTR$ =GN$ + CHR$(32) + SVAL$ + CHR$(32) + LK$ + CHR$(32) + CHR$(13) + CHR$(10)

PRINT #1 DISPSTR$;PRINT TO PORT #1 (#2 FOR PORT 2)

Toledo Indicators (with high speed data format) - Most Toledo indicators support this format. Older
indicators can only be set up as “current loop” (active) at 4800 baud. RS-232 and 20 mA current loops
are supported. Baud rates of 300 - 19,200 may be used. Use the Toledo receiver for these meters.

Flex-Weigh DWM-4 - This indicator can be set up for either “current loop” (active or passive) or
“RS232”, using “MODE 1 - Status, Weight, Tare Data”. Baud rates of 300 - 19,200 may be used. Set the
data preamble to “

FF, FF, FF

” and the postamble to “

FF, FF, FF

”. The LB/KG units display does not

function with this meter. Use the Flex-Weigh receiver for this meter.

Analogic AN5315, AN5316, AN5322, Rice Lake IQ plus 310* - These indicators can be set up for
“current loop” in the continuous mode. Do not use “RS-232.” Baud rates of 300 - 19,200 can be used.
This meter supports the grams and tons display mode. Use the Analogic receiver mode for these meters.

Masstron M2500, M5000, Toledo meters with this output (814X) - These indicators are set up for 4800
baud via the continuous remote display output normally used with Masstron accessories. This meter
supports the grams and tons mode. Use the Masstron receiver for these meters.

Fairbanks 90-164 - This indicator is set up for 1200 baud “current loop” via Port “C”. Enable the
Lampbank output in the continuous mode. Other Fairbanks meters such as the 90-167 will work with the
RD-300/RD-232 if they have continuous data outputs. Use the Fairbanks receiver for these meters.

Streeter Amet 9000 - This indicator is set up for “current loop”. The baud rate can be 1200, 2400, or
4800. Do not use 9600 baud! Program the output for Gross/Net Weight as 01/10/00 or in the print
program for 03/10/00. Use the Universal receiver for this meter.

Cardinal 738 and 748, Rice Lake IQ plus 310* - These indicators can be set up for either the “current
loop” or “RS232”, using the “computer” setting (S3=10001010). The baud rate can be 1200, 2400, 4800,
or 9600. This meter supports the tons display annunciator. Use the Cardinal interface for these meters.

Doran Indicators and Scales - Models 4100 and 4200 are supported. Use either port one or two in either
RS-232 or 20 mA current loop mode. Set the selected output port for continuous data and print format
#11.

Note: The RD-300/RD-232 does not support the lbs and ounces mode!

GSE 450/550 - Models 450 and 550 are supported. A sample program and port configuration is shown
below:

RS-232

Printer Port - RS-232 or current loop

COM port - RS-232 with no handshake

Set number of characters transmitted per number to 8 <

P208.08

>