Rice Lake RD-300 Remote Display User Manual

Page 14

Advertising
background image

12

RD-300/RD-232 Installation & Operation Manual

Other meters may transmit data intermittently, slowly, or in a demand mode where the data is only sent once.
Enabling the time out function causes the RD-300/RD-232 to do the following. If new data hasn't been received
for approximately two seconds, then the display shows what is selected by SW2-5, either the last valid weight or
all dashes. If no valid data is received after ten seconds, the RD-300/RD-232 initiates a power on reset, clear all
data, read the switches, and waits for new data. For these meters SW2-4,5,6 and 7 have the following meanings:

Time Out Enable

SW2-7

Time out counter disabled (cn dis)

Off

Time out counter enabled (cn ena)

On

Table 2-7. SW2-7 Time Out Enabled Setting

Display on Time Out

SW2-5

“No sig”

On

Last data received

Off

Table 2-8. SW2-5 Time Out Settings

Universal KG Character Type

SW2-6

A single character is sent, K, k

Off

KG, Kg, or kg is sent

On

Table 2-9. SW2-6 Character Type Settings

Retransmit Data Format

SW2-4

Condec data format (rd con)

On

As received (rd rec)

Off

Table 2-10. SW2-4 Data Format Settings