MAS-P Animal Scale Operator’s Manual

2.5.1

Battery Mount – Optional

Note

The mounting of the optional battery box differs slightly depending on
the scale size.

Figure 2-8. Battery Mount

1. Mount the upper mounting bracket with the 5/16 x 3/4” bolts supplied, utilizing

the existing wall panel bolt holes. See Figure 2-9.

2. Hang the battery bracket from the upper mount and install the 5/16 x 3/4” bolts

that are supplied.

3. Drill a 3/8” hole through the wall panel aligned with the lower mounting tab.
4. Sandwich the battery strap between the lower mount and the cage wall.
5. Install the 5/16 x 1/2” carriage bolt.
6. Route the indicator conduit from the control box to the battery as shown in

Figure 2-9.

7. Install the lower 90° conduit connector into the mounting tab.
8. Route the scale cable to the connector located to the left.
9. Route the power wire to the battery, see Figure 2-9.