9

MAS-P Animal Scale Operator’s Manual

3.0

Installation

As with any weighing equipment, the accuracy of the scale is dependent on the
installation. The following points must be adhered to when installing the MAS-P
Animal Scale.

3.1 All Installations

In all installations, the scale must be level to ensure proper operation. All MAS-P
Animal Scales are equipped with a bubble level (located on top the base frame – see
Figure 3-1). Ensure the bubble is fully inside the circle marked on the top of the level.

3.2 Permanent Installation

Rice Lake Weighing Systems recommend a concrete foundation (piles or piers) for
permanent installations. The foundation must be able to support the gross weight of
the scale (scale dead weight plus scale capacity), and the piles or piers must be
situated directly under the load cell stands (see shimming location in Figure 3-1). The
foundation must not be subject to distortion or motion due to frost action. A qualified
local professional should be consulted to recommend the proper size of foundation for
the location. Foundation dimensional requirements are available from the dealer or
Rice Lake Weighing Systems. Requirements may vary from one Weights and
Measures jurisdiction to another, please contact the local office.

3.3 Portable Installation

The MAS-P is ideal for use in many locations. Simply load and unload the scale as
described in the Section 1.3 on page 7. Locate the scale in as level a location as
possible, and shim (with wood or metal shims) under the load cell stands to ensure the
scale is level as described above. Please contact the local Weights and Measures
office regarding the moving of the scale to ensure the validity of the certification.

Scale Cable

Bubble Level

Figure 3-1. Shim/Load Cell Stand Locations

3.4 Switching Between Modes

3.4.1

Converting to Weigh Mode

1. Place the scale in as level a location as possible. Ensure there are no obstructions

under the deck that would affect weighing accuracy. Check the bubble level. Use
shims or timbers to ensure the scale is as close to level as possible.

Advertising