0 service information, 1 troubleshooting guide, 2 periodic maintenance – Rice Lake RoughDeck Rough-n-Ready System User Manual

Page 13: Service information, 1 troubleshooting guide 4.2 periodic maintenance

Advertising
background image

Service Information

9

4.0

Service Information

4.1

Troubleshooting Guide

Table 4-1. Troubleshooting

Issue

Possible Cause

Solution

System does not operate -
no display

Power disconnected.

Check and reconnect.

Indicator fuse blown.

Replace fuse. Check for cause.

Interface cable cut or disconnected.

Repair.

Signal leads incorrectly installed at indicator.

Install according to indicator installation manual

Display stays at zero

Indicator faulty.

Service indicator

Load cell connections faulty.

Check cable connections in junction box and at
indicator

Erratic weights

Vibration near scale.

Remove source of vibration or move scale.

Platform not level to within 1/4 inch

Level scale by adjusting feet or shimming if
necessary.

Load cell or cable water damage

Replace

Debris under load cells or platform

Clean

Indicator faulty

Use simulator to test indicator for stability.
Service indicator.

Consistently high or low
weights

Indicator not properly adjusted to zero:

Zero the indicator according to indicator
manual.

Platform binding.

Obtain adequate clearance for free platform
movement.

Indicator not calibrated.

Calibrate according to indicator manual and
Section 3.3 on page 8

Load cells faulty.

Test and replace load cells if necessary.

Feet touching deck underside.

Adjust feet downward to provide clearance.

4.2

Periodic Maintenance

The space between the platform side and pit frame, and the surface beneath the platform must be periodically

cleaned to prevent debris build up. More frequent cleaning of these areas is necessary with scales mounted in pits.

CAUTION

Do not attempt to use scales with load cells that are not hermetically sealed in washdown applications.
Water damage is a common cause of failure in non-hermetically-sealed load cells. Use care with high
pressure steam wash downs for hermetically-sealed load cells. The steam may not damage the load cells,

but the elevated temperatures may cause incorrect readings until the unit cools to room temperature.