background image

Introduction

7

Figure 1-3. RS-485 Serial Connection

If the RS-485 network is longer than 100 meters or baud rates higher than
9600 are used, connect two 120 ohm terminating resistors between the
‘+’ and ‘–’ terminal strip ends of the instruments farthest away. Should
there be different instruments or converters, refer to the specific manuals
to determine whether it is necessary to connect the above-mentioned
resistors.

1.4

Analog Output Type Selection

Set the indicated DIP switch with MODE.

By default, the instrument is calibrated to convert the load cell 0

-

10 mV to the

selected analog output value.

By modifying the type of analog output, calibration will be brought back
to default values.

DIP SWITCH

OPERATION MODE

1

2

3

OFF

OFF

OFF

0-5 V

OFF

OFF

ON

0-10 V

OFF

ON

OFF

-5-5 V

OFF

ON

ON

-10-10 V

ON

OFF

ON

4-20 mA (default)

ON

ON

OFF

0-20 mA

SCT-30

SCT-30

SCT-30

RS485 +
RS485 -

max 500 m

RS485 +

3 2 5

PC RS232

RX+

RX-

TX-

TX+

CONVLAU

24 Vcc

+

-

0

TX
RX

VIN

RS485 +
RS485 -

RS485 -

0 VDC

RS485 +

RS485 -

0 VDC

RS485 +

RS485 -

0 VDC