14

Survivor PT - Pit Type Truck Scale

5.0

Cable Installation

5.1

Load Cells to J-Box

Figure 5-1. J-Box Wiring and Conduit Runs for a Four Section/Three Module Scale

If using a single center module, some of the conduit runs are not used. These conduit runs are used when
more than one center module is installed.

Load Cell
Cable to
Connector

Pocket 1 Conduit

Pocket 8 Conduit

Pockets 1, 2, 3, 4
Conduit runs to J-Box

Pocket 5 Conduit

Module A

Module B

Pocket 3 Conduit

1

8

2

7

SI - Green

SI - White
EX - Red
EX - Black

SHD - Shield

+

-

+

-

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

J3

J4

J7

J8

J6

J5

J2

J1

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

+SI

-SI

+EX

-EX

SHD

Load Cell #1

Load Cell #3

Load Cell #8

Load Cell #6

Load Cell #2

Load Cell #4

Load Cell #7

Load Cell #5

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

SHD - Shield

+SI
-SI

+EX

-EX

SHD

-SEN

+SEN

Indicator/J10

Expansion/J9

Cable to Indicator

SI - Green

+

SI - White

-

EX - Red

+

EX - Black

-

SEN - Yellow

-

SEN - Blue

+

Pocket 4 Conduit

Pocket 6 Conduit

6

3

Pocket 4 Conduit

Pocket 5 Conduit

5

4

Module C

Note