32

troUBlESHootIng

ProBlEm

PoSSIBlE CaUSES

WHat to do

no steam is generated.

Machine is not

turned On.

Ensure the machine is

plugged in, switched On

at the power outlet and the

POWER button is pressed

On.

Water tank is empty.

Refer to ‘Filling The Water

Tank’, page 11.

Steam Dial is not in

STEAM position.

Turn the steam dial to the

STEAM position.

Steam Wand is blocked.

Use the pin on the cleaning

tool to clear the opening. If

the steam wand continues

to be blocked remove the

tip of the steam wand using

the spanner in the middle

of the cleaning tool. Refer

to ‘Care and Cleaning’,

page 25.

milk is not creamy
after texturing.

Not enough steam.

Steam wand may be

blocked. Refer to ‘Care and

Cleaning’, page 25.
Use cold fresh milk. Refer

to ‘Texturing Milk’, page 19.

machine is not working.

The safety thermal-cut

may have activated due

to the pump or grinder

overheating.
Turn the machine off and

allow to cool for about

30–60 minutes.