WARNING:


Do not install hose ends until proper hose length has been determined.

Never install a hose in a location where it will rub against an abrasive surface or
sharp edge or corner.

Do not position hoses with tight bend radii. Consult the hose manufacturers
installation guidelines. Tight bends may kink and cause serious damage to the
system and will void the system’s warranty.

Use caution when tightening the hose ends to prevent the hose from becoming
twisted.

Never install a 90° fitting at the pump inlet or outlet. Avoid the use of flow
restricting fittings.

Do not form loops in the hose that may collect air or kink. Run hoses as straight as
possible (but not taut) between connections.

Do not exceed hose lengths of 20 feet.



6.

SPS model HR-30 can be mounted on top of a vehicle, in the open, without
requiring any additional coverings. Reference Figure 3, Figure 4 and Figure 5 for
the minimum clearances around the perimeter of the generator tray assembly.
Also, do not position any obstructions directly in front of the system’s oil cooler. If
the system cannot be installed without maintaining the minimum clearances as
indicated, or if you have any questions relative to the installation of these systems,
contact Smart Power

®

Systems at (231) 832-5525.