Smart Power Systems HR-30 (3-Phase) User Manual

Page 26

Advertising
background image

Smart Power

®

Systems

A. C. MODULAR GENERATOR SYSTEM

Page 25 of 52

enabled, the purge option will remain set until automatically reset by the system
controller. The system controller will reset the option once the following two
conditions are met:

1. The hydraulic system has been purged for a total of at least 30 minutes.
2. Of those 30 minutes, at least 20 occurred with the generator on.

WARNING:


Never operate the system without the filler/breather plug installed. Contaminants
may enter the hydraulic fluid through the filler opening, causing premature wear on
the hydraulic components and void the system’s warranty.

Never apply a load to the generator while there is air trapped in the hydraulic fluid.
Damage to the system’s hydraulic components, as well as ruptured hoses, may
result and void the system’s warranty.

Always run the purge cycle after installation, after replacing the hydraulic fluid and
the filter, or after making any other repairs that may allow air into the hydraulic
system. Failure to do so will void the system’s warranty.



Enabling System Purge Option

The purge option can also be set by performing the following steps:

Step 3: Hold Mode
until Amps Line 1
Blinks

88. Release

switch so

0Pt

appears.

Step 4: Press mode to
make

Pvrg appear.

Step 5: Press On/Off
until y appears.

Figure 12

1. If the Command & Control Center is dark, press the Mode switch to put

the display into Normal mode.

2. If the Display looks like Figure 12, The purge option is enabled.
3. Otherwise, press and hold the Mode switch until the Amps Line 1 field

begins blinking

88 (more than 10 seconds). Release the switch so 0Pt

appears. reference Figure 12.

4. Press (and release) the Mode switch until

PvrG appears.

5. Press the On/Off switch until a

y appears, indicating Purge option is

Active.

Advertising