Fault_protocol_write_failed – 406h, Cause, Solution – ThingMagic Micro Hardware User Manual

Page 81: Fault_not_implemented_for_this_protocol – 407h, Fault_protocol_invalid_write_data – 408h, Fault_protocol_invalid_address – 409h

Advertising
background image

Protocol Faults

A D I V I S I O N O F T R I M B L E

76

Appendix A: Error Messages

FAULT_PROTOCOL_WRITE_FAILED – 406h

Cause

An attempt to modify the contents of a tag failed. There are many reasons for failure.

Solution

Check that the tag is good and try another operation on a few more tags.

F

AULT_NOT_IMPLEMENTED_FOR_THIS_PROTOCOL – 407h

Cause

A command was received which is not supported by a protocol.

Solution

Check the documentation for the supported commands and protocols.

FAULT_PROTOCOL_INVALID_WRITE_DATA – 408h

Cause

An ID write was attempted with an unsupported/incorrect ID length.

Solution

Verify the Tag ID length being written.

FAULT_PROTOCOL_INVALID_ADDRESS – 409h

Cause

A command was received attempting to access an invalid address in the tag data address

space.

Solution

Make sure that the address specified is within the scope of the tag data address space
and available for the specific operation. The protocol specifications contain information
about the supported addresses.

Advertising