Advanced Tag Operations

Level 2 API

53

Gen2.IDS.SL900A.SetPassword

The SET PASSWORD command writes a 32-bit password to the EEPROM. The
password protection for the specified area is automatically enabled if the password is any
other value except 0.

Gen2.IDS.SL900A.SetShelfLife

The SET SHELF LIFE command programs parameters for the dynamic shelf life
algorithm.

Gen2.IDS.SL900A.SetSFEParameters

The SET SFE PARAMETERS command writes the Sensor Front End parameters to the
memory. Those parameters include the range preset values for the external sensor
inputs, external sensor types and the also the sensor that will be used for limits
comparison.

Gen2.IDS.SL900A.StartLog

The START LOG command starts the logging process. It refreshes the data in the
calibration registers, enables the RTC, writes the Start time and sets the Active bit in the
“System status” field in the EEPROM.

ISO18000-6B TagOps

Note

Cannot be used through

Embedded TagOp Invocation

, only via

Direct Invocation

and must be invoked with an Iso180006b.TagData

TagFilter Interface

.

Iso180006b.ReadData

Read the specified number of data bytes starting at the specified byte-offset memory
location.

Iso180006b.WriteData

Write the specified data starting at the specified byte-offset memory location.